Codemark Certified Organisations

A and AC Building Materials Pty Ltd

Certificate Number10E7BFBC66528723CA257FFE0041CE0A
Type of CertificationProduct Certification
StatusActive
Organisation NameA and AC Building Materials Pty Ltd
Suburb / CitySmithfield
CountryAustralia
CertificationProduct description TZ-AAC 75mm Reinforced Autoclaved Aerated Concrete (AAC) Panel Product purpose or use Non-loadbearing internal partition wall systems providing fire separation and acoustic insulation Complies with the National Construction Code 2016: 1. Volume One BP1.1(a), (b)(i), (ii), (iii), (x), (xi) and (xii), and BP1.2, and Volume Two P2.1.1(a), (b)(i), (ii), (iii), (x), (xi) and (xii) in respect of structural performance, when designed and constructed in accordance with: · Table 1, and · Tianjin Tianzhu Building Materials Company Ltd [TZ-AAC] High-Rise Residential Internal Wall System, TZTM-002, May 2015 Edition 2. Volume One CP1, CP2, and CP4, and Volume Two P2.3.1, in respect of fire performance, when designed and constructed in accordance with the fire-rated construction specifications and details in the Tianjin Tianzhu Building Materials Company Ltd [TZ-AAC] High-Rise Residential Internal Wall System, TZTM-002, May 2015 Edition and the following AS 1530.4: 2005 fire-resistance test parameters to achieve a FRL of -/120/120 in one direction: · 3.0m max. wall height · Minimum 10mm standard grade plasterboard on the non fire-side face of the wall. 3. Volume One FP5.2 and FP5.5, and Volume Two P2.4.6 in respect of acoustic performance of walls separating sole-occupancy units, when detailed and constructed in accordance with: · Volume One Specification F5.2 · Volume Two Part 3.8.6, and · Tianjin Tianzhu Building Materials Company Ltd [TZ-AAC] High-Rise Residential Internal Wall System, TZTM-002, May 2015 Edition. 4. Volume One JP1 and Volume Two P2.6.1 in respect of energy efficiency of walls when designed and constructed in accordance with: · Table 1, and · Tianjin Tianzhu Building Materials Company Ltd [TZ-AAC] High-Rise Residential Internal Wall System, TZTM-002, May 2015 Edition. In applications where complying thermal resistances of walls are to be calculated, a thermal resistance of R 0.6 m2.K/W shall be used for the 75mm TZ AAC panel. State Addit
Certification Standard(s)BCA - all clauses
Certification Code(s)
Date Certified28/07/2016
Certified byGlobal-Mark Pty Ltd